# 质量追溯系统 (Scanner Record)
西门子 S7 PLC 测量数据自动采集与追溯系统。
## 目录结构
```
scanner_record/
├── project/ # TypeScript 项目(主程序)
│ ├── .env # 配置文件(gitignored)
│ ├── .env.example # 配置示例
│ ├── src/
│ │ ├── index.ts # 入口:HTTP + PLC 轮询
│ │ ├── logger.ts # 分级日志 + 按天滚动保留 7 天
│ │ ├── types.ts # 共享类型
│ │ ├── database/
│ │ │ ├── connection.ts # SQLite 连接(WAL)
│ │ │ └── schema.ts # 建表 / CRUD
│ │ ├── api/
│ │ │ ├── config.ts # 设备配置 API
│ │ │ ├── query.ts # 追溯 + 互锁 API
│ │ │ └── monitor.ts # 状态 API
│ │ ├── plc/
│ │ │ ├── protocol.ts # 地址偏移 / ControlWord
│ │ │ ├── client.ts # Snap7 读写 + TCP 探测
│ │ │ └── scanner.ts # 轮询 + 断线重连
│ │ └── services/
│ │ ├── collection.ts # 采集入库
│ │ └── interlock.ts # 工序互锁
│ ├── web/ # 前端(Vite + Tailwind CDN)
│ │ └── src/
│ │ ├── main.ts # 追溯 / 配置(二级标签)
│ │ └── api/client.ts # 后端 API 封装
│ ├── test/
│ │ ├── plc-comm.ts # PLC 通信诊断
│ │ └── README-PLC.md
│ └── data/ # SQLite(gitignored)
├── plc_protocol_design.md # PLC 协议文档
├── pc_database_design.md # PC 数据库设计
├── test_snap7.py # PLC 测试工具(Python CLI)
├── db_init.py / simulate.py # 旧版原型(参考)
├── FLOWCHART.md # Mermaid 流程图
├── README.md
└── .gitignore
```
---
## 项目进展
### ✅ 已完成
- [x] PLC 端协议设计(24 字节/工序,ControlWord 位定义)
- [x] PC 端数据库设计(按检测点分表,每天一张)
- [x] TypeScript 后端骨架(Hono + better-sqlite3 + node-snap7)
- [x] 前端 Vite 项目(Tailwind CSS,追溯查询 + 设备配置)
- [x] 数据库 CRUD API(检测点 / PLC / 工序 增删改查)
- [x] PLC 轮询扫描(每秒一次,批量读取所有工序)
- [x] 数据自动采集(DataReady=1 → 读取 → 入库 → 清标志)
- [x] 工序互锁(PrevResultReq=1 → 查数据库 → 写回结果)
- [x] 日志系统(分级 + 时间戳 + 模块标签 + 按天滚动保留 7 天)
- [x] 启动时自动建库(空数据库也能直接启动)
- [x] PLC 通信诊断工具(`npm run test:plc`)
- [x] 前端在线配置(检测点 / PLC / 工序 增删改)
- [x] `.env` 配置文件(轮询间隔、日志级别、断线参数)
- [x] PLC 断线自动重连机制(TCP 探测 + 状态机)
- [x] 批量 DB 读取(一次网络请求读完所有工序)
- [x] 测试脚本 `test_snap7.py` 命令行参数化
### 🚧 待完成
- [ ] 数据导出(CSV / Excel)
- [ ] ECharts 趋势图
- [ ] 用户登录 / 权限管理
- [ ] Windows 服务注册(开机自启)
---
## 快速开始
### 环境要求
- **Node.js** 22.x(node-snap7 不兼容 v25+)
- **npm** 11+
- **Python** 3.x(仅测试脚本需要)
### 配置
创建 `project/.env`(可从 `.env.example` 复制):
```ini
PORT=3000 # 服务端口
POLL_INTERVAL_MS=1000 # PLC 轮询间隔(毫秒)
LOG_LEVEL=1 # 日志级别: 0=DEBUG, 1=INFO, 2=WARN, 3=ERROR
PLC_FAIL_LIMIT=3 # 连续失败次数上限
PLC_PROBE_INTERVAL_MS=5000 # TCP 探测间隔(毫秒)
PLC_PROBE_TIMEOUT_MS=2000 # TCP 探测超时(毫秒)
# SKIP_PLC=1 # 跳过 PLC 连接(开发用)
```
### 启动
```bash
cd project
# 安装依赖
npm install
cd web && npm install && cd ..
# 构建前端
cd web && npm run build && cd ..
# 启动(无 PLC 模式,开发调试)
SKIP_PLC=1 npm run start
# 启动(连接真实 PLC)
npm run start
```
### 前端开发(热更新)
```bash
# 终端 1:后端
cd project && npm run dev
# 终端 2:前端(HMR)
cd project/web && npm run dev
```
---
## 架构
```
┌──────────────────────────────────────────────────────┐
│ 西门子 S7 PLC │
│ DB 块:工序 0 (偏移 0) | 工序 1 (偏移 24) | ... │
│ ControlWord: DataReady / IsQualified / PrevResultReq│
└──────────────────────┬───────────────────────────────┘
│ S7 协议 (Ethernet)
┌──────────────────────▼───────────────────────────────┐
│ Node.js 进程 (Hono) │
│ │
│ ┌─────────────┐ ┌──────────────┐ │
│ │ PLC Scanner │ │ REST API │ :3000 │
│ │ (1s 轮询) │ │ /api/* │ │
│ └──────┬───────┘ └──────┬───────┘ │
│ │ │ │
│ ┌──────▼────────────────▼───────┐ │
│ │ better-sqlite3 │ │
│ │ data/production.db │ │
│ └──────────────────────────────┘ │
└──────┬───────────────────────────────────────────────┘
│ 静态文件 (/web/*)
┌──────▼───────────────────────────────────────────────┐
│ 前端 (Vite 构建产物) │
│ 追溯查询 / 设备配置 / 系统状态 │
└──────────────────────────────────────────────────────┘
```
---
## PLC 通信协议
| 字段 | 偏移 | 类型 | 大小 | 方向 | 说明 |
|------|------|------|------|------|------|
| ProductID | +0 | DINT | 4 | PLC→PC | 当前产品唯一编号 |
| UpperLimit | +4 | REAL | 4 | PLC→PC | 测量上限 |
| LowerLimit | +8 | REAL | 4 | PLC→PC | 测量下限 |
| MeasuredValue | +12 | REAL | 4 | PLC→PC | 实测值 |
| ControlWord | +16 | WORD | 2 | 双向 | 控制字(见下方) |
| Reserved | +18 | — | 6 | — | 保留 |
### ControlWord 位定义
| 位 | 名称 | 方向 | 说明 |
|---|------|------|------|
| Bit 0 | DataReady | PLC→PC | 1=有新的测量数据待读取 |
| Bit 1 | IsQualified | PLC→PC | 1=合格 |
| Bit 2 | PrevResultReq | PLC→PC | 1=请求上一工序结果 |
| Bit 3 | PrevResult | PC→PLC | PC 写入:1=合格,0=不合格 |
详见 `plc_protocol_design.md`。
---
## API 文档
### 基础信息
- **Base URL**: `http://localhost:3000/api`
- **Content-Type**: `application/json`
---
### 设备配置
#### `GET /api/config/plcs`
获取所有 PLC。
```json
[
{
"Id": 1,
"PLCName": "PLC01_焊接段",
"IPAddress": "192.168.0.10",
"DBNumber": 100,
"StationCount": 3
}
]
```
#### `POST /api/config/plcs`
新增 PLC。
```json
// Request
{ "PLCName": "PLC01", "IPAddress": "192.168.0.10", "DBNumber": 100 }
// Response
{ "Id": 1 }
```
#### `PUT /api/config/plcs/:id`
修改 PLC。
```json
{ "PLCName": "PLC01", "IPAddress": "192.168.0.11", "DBNumber": 200 }
```
#### `DELETE /api/config/plcs/:id`
删除 PLC(级联删除关联工序)。
---
#### `GET /api/config/measurement-points`
获取所有检测点。
```json
[
{ "Id": 1, "PointName": "焊接温度", "FieldUnit": "℃" }
]
```
#### `POST /api/config/measurement-points`
新增检测点(自动创建对应数据表)。
```json
{ "PointName": "焊接温度", "FieldUnit": "℃" }
```
---
#### `GET /api/config/stations`
获取所有工序。支持 `?plcId=1` 过滤。
```json
[
{ "Id": 1, "PLCId": 1, "StationIndex": 0, "StationName": "预焊接", "PointId": 1, "pointName": "焊接温度" }
]
```
#### `POST /api/config/stations`
新增工序。不传 `StationName` 时自动取检测点名。
```json
{ "PLCId": 1, "StationName": "预焊接", "PointId": 1, "StationIndex": 0 }
```
---
### 数据查询
#### `GET /api/query/:productId`
查询某产品在所有检测点的测量数据。
```json
{
"productId": "PROD-003",
"data": [
{
"pointId": 1,
"pointName": "焊接温度",
"fieldUnit": "℃",
"recordTime": "2026-06-08 07:54:42",
"isQualified": 1,
"inspectionCount": 1,
"upperLimit": 93.3,
"lowerLimit": 75.2,
"measuredValue": 90.2
}
]
}
```
#### `GET /api/query/:productId/interlock/:stationName`
查询某产品在某工序的上一工序合格情况。
```json
{
"currentStation": "焊后检测",
"currentPoint": "焊点直径",
"prevStation": "主焊接",
"prevPoint": "焊接电流",
"prevResult": 1
}
```
### 监控
#### `GET /api/monitor/status`
```json
{
"plcCount": 2,
"stationCount": 5,
"pointCount": 5,
"dataTableCount": 5,
"totalRecords": 60
}
```
---
## 数据流
### 采集流程
```
PLC: ControlWord.DataReady = 1
↓
PC: 读 DB 块 32 字节 → 解析 ProductID + 测量值 + ControlWord
↓
PC: 查数据库 → InspectionCount = max + 1
↓
PC: INSERT/UPDATE → MPData_P{PointId}_{日期}
↓
PC: ControlWord.DataReady = 0
```
### 互锁流程
```
PLC: ControlWord.PrevResultReq = 1
↓
PC: 读 DB → 获取 ProductID
↓
PC: 查数据库 → 前工序的最新 IsQualified
↓
PC: ControlWord.PrevResult = 1/0
↓
PC: ControlWord.PrevResultReq = 0
```
---
## 数据库结构
### 配置表
```
MeasurementPoints (Id, PointName, FieldUnit)
PLCs (Id, PLCName, IPAddress, DBNumber, StationCount)
Stations (Id, PLCId, StationIndex, StationName, PointId)
```
### 数据表(按检测点分表,每天一张)
```
MPData_P1_2026_06_08:
Id | ProductID | RecordTime | IsQualified | InspectionCount |
UpperLimit | LowerLimit | MeasuredValue
```
---
---
## PLC 断线重连机制
```
正常轮询 ── 连续失败 N 次 ──→ TCP 探测模式 ──→ 端口恢复 ──→ 重连 ──→ 正常轮询
```
- 连续读取失败 `PLC_FAIL_LIMIT`(默认 3)次后,停止对该 PLC 的 DB 读取
- 进入 TCP 探测模式,每 `PLC_PROBE_INTERVAL_MS`(默认 5s)检查一次 TCP 102 端口
- 端口恢复后自动调用 Snap7 `ConnectTo` 重连,成功后回到正常轮询
- 失败期间控制台**不刷屏**,只输出关键状态变更
---
## 测试工具
`test_snap7.py` 用于手动向 PLC 写入测试数据:
```bash
# 写入工序 0 完整数据 + 触发采集
python test_snap7.py --station 0 --product-id 10086 --upper 100.0 \
--lower 80.0 --measured 95.5 --dataready --qualified
# 工序 2 触发 PrevResultReq
python test_snap7.py --station 2 --prev-req
# 只读某一工序
python test_snap7.py --station 1 --read
# 触发 DataReady + 不合格
python test_snap7.py --station 0 --dataready --unqualified
```
### 参数说明
| 参数 | 说明 |
|------|------|
| `--ip` | PLC IP(默认 192.168.2.125)|
| `--db` | DB 块号(默认 1)|
| `--station` | 工序索引(默认 0)|
| `--read` | 读取本工序所有字段 |
| `--product-id` | 写入 ProductID (DINT) |
| `--upper / --lower / --measured` | 写入上限/下限/实测值 (REAL) |
| `--dataready` | 设置 ControlWord Bit0=1 |
| `--qualified` | 设置 Bit1=1(合格)|
| `--unqualified` | 设置 Bit1=0(不合格)|
| `--prev-req` | 设置 Bit2=1 (PrevResultReq) |
| `--value` | 直接写入 ControlWord 值 |
---
## 常见问题
### node-snap7 报 TypeError: Wrong arguments
Node.js v25+ 与 `node-snap7` 的 C++ 绑定不兼容。需降级到 Node.js 22.x:
```bash
nvm install 22
nvm use 22
npm rebuild node-snap7
```
### PLC 连接失败
使用诊断工具排查:
```bash
cd project
npm run test:plc -- <PLC_IP> 0 2
```
### 启动报 SQLITE_IOERR
删除旧的 WAL 文件后重试:
```bash
rm -f project/data/production.db*
```